Summary
Analytical Precision in Critical Systems
Within industries where contamination control is paramount, analytical precision contributes immensely to system reliability. Analytical testing provides insight into the condition of high-purity utility systems and process equipment, and ensures their continued compliance with stringent quality requirements.
Modern contamination control programs address two fundamental questions: “What’s in my process stream?” and “What’s on my equipment?”
Utility System Sampling and Health Analysis
Comprehensive analysis is the foundation of a well-structured contamination control program in a high purity utility system. Analysis should cover both the amount and size of contamination present in the utility system, as well as the chemical composition of the contamination. Particulate analysis according to ASTM F311 and F312 returns the number of particles within discrete size bins in a sample, while Inductively Coupled Plasma Mass Spectroscopy (ICP-MS) analysis determines the elements present in the sample, as both solid or dissolved compounds.
Sampling Strategy for a Utility System
Sampling points are strategically selected throughout the purified water system to capture representative data on particulate and trace metal ions present. Samples should be taken near the final piece of purification equipment, i.e. the distillate line of a WFI still, from points of use on the supply side, and from the utility return line. If a steam utility is being sampled, condensate out of steam traps can be captured as a sample. Best practice is to sample a utility system before and after major shutdown remediation to understand the particulate and elemental contaminant levels of a dirty and as-remediated system, respectively. These results establish baseline conditions and an alert or action condition that allows for trend tracking and early detection of deviations. Sampling is best performed quarterly to determine the rate of particulate generation in the system.
Industry Benchmarking: USP and IEST Standards
Alert and action limits for particulate levels in a high-purity utility system can reference levels defined in specific chapters of the United States Pharmacopeia (USP) and/or IEST-STD-CC1246. IEST-STD-CC1246 is a standard that defines particulate and nonvolatile residue cleanliness levels and is heavily utilized in the Aerospace industry.
| Pharmacopoeia Chapter | Chapter Title | Sample Size | Particles ≥ 10 µm | Particles ≥ 25 µm | Particles ≥ 50 µm | Approx. IEST-STD-CC1246 Level |
|---|---|---|---|---|---|---|
| USP 787* | Therapeutic Protein Injections | ≤ 100 mL | 6000 per container |
600 per container |
N/A | Level 200 |
| > 100 mL | 25 per mL |
3 per mL |
N/A | Level 100 | ||
| USP 788** | Parenteral Injections | ≤ 100 mL | 3000 per container |
300 per container |
N/A | Level 200 |
| > 100 mL | 12 per mL |
2 per mL |
N/A | Level 100 | ||
| USP 789** | Ophthalmic Solutions | N/A | 50 per mL |
5 per mL |
2 per mL |
Level 200 |
* Light obscuration test method; ** membrane microscopy method
ICP-MS: Trace Metals Analysis
ICP-MS is the preferred technique for trace metal detection at part-per-trillion sensitivity. The method ionizes samples within a high-temperature plasma and separates ions by mass-to-charge ratio, identifying and quantifying metallic species. This analytical technique is widely applied to monitor contamination in process fluids or waste streams. By correlating ICP-MS results to system history, operators can distinguish between normal material wear and potential contamination sources.
Interpreting Results
Typical sources of contamination in a pure utility system are metals, metal oxides, and polymer particles. Metallic particles are usually stainless steel removed from the internal surface at high velocity or high impact locations, such as a cavitating pump. Metal oxides tend to be rouge particles sloughed off the internal pipe surface and into the utility stream. Polymer particles are shed from plastic components in a system, such as gaskets, valve seats, and filters. The figure below shows a filter pad with contamination from each of these groups emphasized in a cutaway picture.
When partnered with particle count testing, ICP-MS analysis allows the system owner to understand how many particles there are, how large the particles are, and elemental composition of the particles present in the sample. A result with a high concentration of iron but low chromium suggests excessive rouge, high calcium or magnesium can originate from untreated city water or incompletely purified water, and high amounts of fluorine may be caused by a failed Teflon gasket shedding particulate into the process stream. Understanding the chemical concentrations help determine the correct remediation. Gasket replacement of a WFI system can be accomplished more quickly than cleaning, derouging, and re-passivation of the system, plus it is the more correct action over chemical processing if high fluorine and zero iron nor chromium were analyzed by ICP-MS. The combination of both analyses allows for full insight into system health and the actions needed to maintain that health.
Surface Contamination: What’s on My Equipment?
Process equipment surface integrity plays a critical role in system cleanliness along with utility and process fluid purity. Over time, process equipment surfaces can accumulate a wide variety of residues like rouge, residual product, residual cleaning chemical, and bacteria, all of which can be undetectable to the naked eye. Surface analysis identifies the elements present in the contaminant, and that data can be used to determine the contamination source and ideal method of remediation.
SEM & EDS: Metallic Contamination Analysis
When metallic contamination is suspected, Scanning Electron Microscopy (SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) provides the most detailed characterization. SEM offers micrometer-scale imaging that reveals particle structure and morphology. EDS complements the SEM image by identifying the elemental composition of each particle found in the SEM image.
Commonly identified elements analyzed from contamination on stainless steel equipment include iron (Fe), chromium (Cr), nickel (Ni), silicon (Si), aluminum (Al), fluorine (F), and chlorine (Cl)—each revealing clues about contaminant origin, surface wear, and cleaning chemistry interactions.
FTIR: Organic and Non-Metallic Contamination
For non-metallic residues, Fourier Transform Infrared Spectroscopy (FTIR) provides compositional information where EDS cannot. FTIR provides a distinct spectrum of the chemical compound by passing infrared radiation through a sample and measuring the change in radiation intensity. By comparing these spectra against reference compound libraries, analysts can identify residues such as residual process or cleaning chemicals, lubricants, or buffing compounds.
Beyond the Numbers: Interpretation and Action
Analytical results become meaningful when interpreted in the context of system design, system process history, and system maintenance history. Lab analysis identifies the elements present in a contamination sample, but lab analysis alone does not provide a conclusive root cause on contamination source nor how to remediate the contamination. Astro Pak combines the analytical technique with an understanding of standard high-purity manufacturing practices to help end users determine contamination sources and the best chemical remediation options to remove the contamination. Further, Astro Pak offers consultation and review of established maintenance practices with the goal of finding improvements that may minimize future contamination or corrosion events.
Continued analysis on the type of compounds that frequently contaminate a system, and the generation rate of that contamination over time results in an understanding of exactly when a system’s ability to produce high quality product is compromised. This understanding can be used to implement a proactive, data-driven maintenance schedule that minimizes system downtime while ensuring quality. Let Astro Pak be your partner in building out this understanding by facilitating your 3rd party analysis needs today.
Frequently Asked Questions
Analytical testing quantifies particulate load, elemental composition and residue type in high purity water and steam systems. The resulting data helps system owners benchmark against standards such as USP and IEST-STD-CC1246, understand system cleanliness trends over time and plan maintenance or remediation before product quality is compromised.
Particulate analysis, ICP-MS, SEM/EDS and FTIR are commonly used together. Particulate analysis and ICP-MS quantify particle counts and elemental composition in utility streams, while SEM/EDS and FTIR identify the metallic or organic residues present on equipment surfaces, including rouge, polymer shedding and residual process chemistry.
Sampling frequency depends on system design, operating conditions and risk tolerance, but quarterly sampling provides a practical baseline for many high purity systems. Sampling before and after major shutdown remediation helps establish baseline, alert and action levels and supports long term trend analysis.